RCA
Dryer Airflow Restriction / Sensor Dry Issue
Washer-dryer combo takes excessively long to dry or never reaches the end of the drying cycle.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Restricted airflow in lint duct or vent, Moisture sensor coated with residue, Faulty moisture sensor, Incorrect cycle selection
How to Fix / Troubleshooting
Safety first: Unplug the unit before cleaning internal ducts or sensors.
- Clean lint path: In addition to the lint filter, clean the internal lint duct and blower housing. Use a vacuum and brush to remove buildup.
- Check vent length (vented models): Ensure the vent run is not excessively long or with too many bends, which can restrict airflow.
- Clean moisture sensor: Locate the metal moisture sensor bars inside the drum (usually near the front). Clean them with a soft cloth and mild detergent to remove fabric softener film.
- Use appropriate cycle: For mixed loads or small loads, use timed dry instead of sensor dry to avoid premature termination.
- When to replace parts: If clothes remain damp and the cycle runs unusually long, replace the moisture sensor or associated wiring harness.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Moisture Sensor Bars
Check Price on Amazon