Roborock
Excess Moisture / Venting or Condenser Inefficiency
Washer-dryer combo shows condensation on control panel and surrounding cabinetry after drying
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Blocked Roborock condenser, Poor room ventilation, Leaking dryer duct joints (vented models), Faulty condenser fan
How to Fix / Troubleshooting
Safety first: Allow the unit to cool and unplug before cleaning internal components.
- Improve room ventilation: Ensure the laundry area has adequate airflow.
- Clean condenser: Access and clean the Roborock condenser and surrounding ducts.
- Check vent hose (if vented): Inspect for kinks, blockages, or disconnected joints.
- Inspect condenser fan: Verify the fan runs during drying; if not, test and replace the Roborock dryer fan motor.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Roborock Condenser Assembly
Check Price on Amazon