E12
Siemens Condenser / Heat Exchanger Blocked

Drying performance poor; E12 displayed; condenser or heat exchanger warning

Advertisements

Possible Causes

Lint-clogged condenser, Blocked air channels, Dirty moisture sensor bars, Faulty airflow sensor (if fitted)

How to Fix / Troubleshooting

Safety first: Unplug the appliance before cleaning internal ducts.

Step-by-step checks:

  • 1. Clean the condenser:
    • Open the condenser flap at the bottom front.
    • Remove the condenser unit and rinse thoroughly under running water until clear.
    • Allow to drain and dry before reinstalling.
  • 2. Clean air channels and filters:
    • Remove and clean the door lint filter.
    • Vacuum lint from visible ducts and around the condenser housing.
  • 3. Clean moisture sensor bars:
    • Locate the metal strips inside the drum (usually near the door opening).
    • Wipe them with a cloth and a little vinegar or mild detergent to remove residue.
  • 4. Check airflow sensor (if present):
    • Inspect wiring and sensor placement in the duct.
    • Replace if damaged or reading incorrectly (requires service data).

When to call a technician: If E12 persists after thorough cleaning, internal ducting or sensors may need professional inspection.

Advertisements

Repair Difficulty

Easy 2/5

Required Part

Condenser Unit
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements