E14
Siemens Flow Meter / Water Intake Measurement Fault

Washer-dryer reports E14; issues with water level detection during drying or wash

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Faulty flow meter in AquaStop assembly, Blocked inlet causing incorrect pulses, Wiring issue between flow meter and control, Control module misreading flow signals

How to Fix / Troubleshooting

Safety first: Unplug the appliance and close the water tap.

Step-by-step checks:

  • 1. Check inlet filters and pressure:
    • Clean mesh filters at the AquaStop hose and machine inlet.
    • Ensure adequate water pressure at the tap.
  • 2. Inspect flow meter (if integrated):
    • On many Siemens units, the flow meter is built into the AquaStop or inlet valve block.
    • Check the small wiring harness from the valve to the control module.
    • Look for damaged or loose connectors.
  • 3. Replace AquaStop / flow meter assembly if faulty:
    • If the flow meter does not generate pulses (requires service test), replace the complete valve/flow meter unit.

When to call a technician: Flow meter diagnosis often requires service mode and specialized tools; professional service is recommended if basic checks do not resolve the issue.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

AquaStop Valve with Flow Meter
Check Price on Amazon