Er14
Speed Queen
Auto-Dry Control / Sensor Circuit Error
Display shows Er14 and dryer runs but timer does not advance in auto cycles
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Faulty moisture sensor circuit, Failed cycling thermostat, Control board auto-dry logic failure, Open thermistor
How to Fix / Troubleshooting
Safety first: Unplug the unit before testing thermostats or sensors.
- 1. Test timed dry: Run a timed dry cycle. If it works normally, the issue is likely in the auto-dry sensor or control logic.
- 2. Recheck moisture sensor: Clean and test as described for Er13.
- 3. Thermostat and thermistor test: Access the dryer heater housing and blower area. Test the cycling thermostat and thermistor for proper resistance at room temperature and compare to specs.
- 4. Replace faulty components: Install new OEM moisture sensor, cycling thermostat, or thermistor as indicated by tests.
- 5. Control board replacement: If all field components test good, the main control's auto-dry circuit may be defective and require replacement.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Cycling Thermostat
Check Price on Amazon
We may earn a commission from links on this page.