Er14
Speed Queen Auto-Dry Control / Sensor Circuit Error

Display shows Er14 and dryer runs but timer does not advance in auto cycles

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Faulty moisture sensor circuit, Failed cycling thermostat, Control board auto-dry logic failure, Open thermistor

How to Fix / Troubleshooting

Safety first: Unplug the unit before testing thermostats or sensors.

  • 1. Test timed dry: Run a timed dry cycle. If it works normally, the issue is likely in the auto-dry sensor or control logic.
  • 2. Recheck moisture sensor: Clean and test as described for Er13.
  • 3. Thermostat and thermistor test: Access the dryer heater housing and blower area. Test the cycling thermostat and thermistor for proper resistance at room temperature and compare to specs.
  • 4. Replace faulty components: Install new OEM moisture sensor, cycling thermostat, or thermistor as indicated by tests.
  • 5. Control board replacement: If all field components test good, the main control's auto-dry circuit may be defective and require replacement.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Cycling Thermostat
Check Price on Amazon