Speed Queen
Overfill / Water Level Control Failure
Washer overfills or water level is too high
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Stuck water inlet valve, Blocked or disconnected pressure hose, Faulty water level sensor, Control board not shutting off fill
How to Fix / Troubleshooting
Safety first: If overfilling, unplug the unit immediately and shut off water supply valves.
- 1. Check inlet valves: With power off, turn water supply back on briefly. If water continues to flow into the tub, the inlet valve is stuck open and must be replaced.
- 2. Inspect pressure hose: Ensure the hose from tub to pressure sensor is connected and not blocked.
- 3. Sensor test: Test the water level sensor as described for Er8. Replace if faulty.
- 4. Control board: If valves and sensor are good but overfill persists, the control board may be defective and require replacement.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Water Inlet Valve Assembly / Water Level Sensor
Check Price on Amazon