Speed Queen Overfill / Water Level Control Failure

Washer overfills or water level is too high

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Stuck water inlet valve, Blocked or disconnected pressure hose, Faulty water level sensor, Control board not shutting off fill

How to Fix / Troubleshooting

Safety first: If overfilling, unplug the unit immediately and shut off water supply valves.

  • 1. Check inlet valves: With power off, turn water supply back on briefly. If water continues to flow into the tub, the inlet valve is stuck open and must be replaced.
  • 2. Inspect pressure hose: Ensure the hose from tub to pressure sensor is connected and not blocked.
  • 3. Sensor test: Test the water level sensor as described for Er8. Replace if faulty.
  • 4. Control board: If valves and sensor are good but overfill persists, the control board may be defective and require replacement.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Water Inlet Valve Assembly / Water Level Sensor