Whirlpool
Condensing Dryer System Leak
Washer-dryer combo leaks water only during drying cycle; water appears at front or bottom.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Blocked condenser or lint trap, cracked condenser housing, loose dryer drain hose, failed water valve for condenser spray
How to Fix / Troubleshooting
Safety first: Unplug the unit and allow it to cool before working near the dryer section.
Step-by-step checks:
- Clean condenser path: If accessible, remove and clean the condenser unit and any lint filters associated with the dryer circuit.
- Inspect dryer drain hoses: Trace the small hoses that carry condensation water to the drain or pump. Check for cracks or disconnections.
- Check condenser housing: Look for signs of water trails indicating cracks or gaps.
When to replace: Replace any cracked condenser housing or leaking hose. Ensure all connections are secure.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Dryer Condenser Assembly
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements