Asko
Hot Water Supply / Valve Issue
Washer does not fill with hot water; only cold water is used even on hot cycles
Advertisements
Possible Causes
Hot water tap closed, Hot inlet hose kinked, Failed hot water inlet valve coil, Incorrect hose connection on Asko inlet block
How to Fix / Troubleshooting
Safety first: Unplug the washer and close water taps before disconnecting hoses.
- Step 1 – Verify hot tap: Ensure the hot water faucet feeding the washer is fully open and hot water is available at nearby taps.
- Step 2 – Check hose: Inspect the hot inlet hose for kinks or blockages. Replace if damaged.
- Step 3 – Confirm connections: Make sure the hot hose is connected to the hot inlet on the Asko valve assembly.
- Step 4 – Test hot valve coil: With power off, measure resistance of the hot valve coil. Replace the inlet valve assembly if the coil is open.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Hot Water Inlet Valve
Check Price on Amazon