E10
Brandt
Fill / Drain Conflict
Washer shows E10 and does not fill correctly; may alternate between fill and drain.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Incorrect drain hose height causing siphoning, Faulty pressure switch, Stuck inlet valve, Software misinterpretation of level
How to Fix / Troubleshooting
Safety first: Unplug the washer.
Check drain hose installation:
- Ensure the hose is not inserted too far into the standpipe and is at the correct height (usually 60–90 cm).
Verify pressure system and inlet valve:
- Inspect and test the pressure switch and hose as for D10.
- Test the inlet valve for proper operation and replace if leaking or stuck.
If E10 continues after correcting installation and components, the PCB may need replacement.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Pressure Switch
Check Price on Amazon
We may earn a commission from links on this page.