E10
Brandt Fill / Drain Conflict

Washer shows E10 and does not fill correctly; may alternate between fill and drain.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Incorrect drain hose height causing siphoning, Faulty pressure switch, Stuck inlet valve, Software misinterpretation of level

How to Fix / Troubleshooting

Safety first: Unplug the washer.

Check drain hose installation:

  • Ensure the hose is not inserted too far into the standpipe and is at the correct height (usually 60–90 cm).

Verify pressure system and inlet valve:

  • Inspect and test the pressure switch and hose as for D10.
  • Test the inlet valve for proper operation and replace if leaking or stuck.

If E10 continues after correcting installation and components, the PCB may need replacement.