E18
Fagor
Extended Drain Time / Partial Blockage
Washer stops with E18; often related to drain time or pump performance
Advertisements
Possible Causes
Partially blocked pump filter, Partially blocked drain hose, Weak drain pump, Siphoning due to incorrect hose installation
How to Fix / Troubleshooting
Safety: Unplug the washer.
- Clean pump filter thoroughly: Remove all lint and small objects as in E03.
- Flush drain hose: Detach and run water through the hose to clear partial blockages.
- Check hose height: Ensure correct installation height to prevent siphoning.
- Assess pump strength: During a drain cycle, observe the flow into the standpipe. A weak trickle with a clear system suggests a failing pump that should be replaced.
Advertisements
Repair Difficulty
Easy
2/5