E18
Fagor Extended Drain Time / Partial Blockage

Washer stops with E18; often related to drain time or pump performance

Advertisements

Possible Causes

Partially blocked pump filter, Partially blocked drain hose, Weak drain pump, Siphoning due to incorrect hose installation

How to Fix / Troubleshooting

Safety: Unplug the washer.

  • Clean pump filter thoroughly: Remove all lint and small objects as in E03.
  • Flush drain hose: Detach and run water through the hose to clear partial blockages.
  • Check hose height: Ensure correct installation height to prevent siphoning.
  • Assess pump strength: During a drain cycle, observe the flow into the standpipe. A weak trickle with a clear system suggests a failing pump that should be replaced.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Drain Pump
Check Price on Amazon

We may earn a commission from links on this page.