Fagor
Intermittent Power or Control Fault
Washer stops mid-cycle and water remains in drum, but no error code is shown
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Loose power plug or socket, Faulty door lock losing contact, Overheating control board, Intermittent pump or motor failure
How to Fix / Troubleshooting
Safety: Unplug the washer.
- Check power connection: Ensure the plug fits tightly in the socket and that there is no extension lead causing drops.
- Inspect door lock: Wiggle the door gently during operation (once safe) to see if the machine stops; if so, replace the lock.
- Check for overheating: After stopping, feel the control panel area; excessive heat may indicate PCB issues.
- Clean pump filter: Ensure the pump is not intermittently blocked.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Door Lock Interlock Assembly
Check Price on Amazon