Possible Causes
Failed heater relay on main control board, Shorted heater causing relay damage, Burnt control board traces
How to Fix / Troubleshooting
Safety first: Disconnect power before working on the control board.
- Inspect heater circuit: Test the heater element for shorts to ground. Replace if defective.
- Inspect main control board: Remove the board and examine the heater relay and surrounding area for burns or cracked solder joints.
- Replace main control board: If the relay or board is damaged, replace the entire control board with the correct Frigidaire part.
- Re-test heating: After reassembly, run a hot wash cycle to confirm proper heating and that E66 is cleared.