Frigidaire
Mechanical Inlet Valve Stuck Open
Washer overflows or continues filling even when power is off
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Debris lodged in water inlet valve, Worn valve seat, High water pressure causing valve not to close fully
How to Fix / Troubleshooting
Safety first: Immediately turn off the hot and cold water supply valves and unplug the washer.
- Confirm valve seepage: With the washer unplugged and water turned on briefly, observe if water flows into the tub. Any flow without power indicates a stuck valve.
- Inspect and replace valve: Remove the top panel, disconnect hoses and wiring from the inlet valve, and replace the valve assembly with a new Frigidaire part.
- Install pressure regulator if needed: If household water pressure is very high, consider installing a pressure regulator to protect the new valve.
- Test fill: After replacement, run a fill cycle and verify that water stops promptly at the correct level and no seepage occurs when off.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Water Inlet Valve Assembly
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements