E71
GE Profile
Water Level Signal Out of Range
Washer shows E71 and may overfill, underfill, or stop with water at an incorrect level.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Pressure hose partially blocked, Sensor calibration drift, Air leak at tub air dome, Control board level calibration fault
How to Fix / Troubleshooting
Safety first: Unplug the washer before inspection.
- Check for over-sudsing: Excess detergent can create foam that interferes with pressure sensing. Run a rinse & spin with no detergent to clear suds.
- Inspect pressure hose and air dome: Verify the hose is firmly attached at both ends and not cracked. Inspect the tub air dome (where the hose connects) for buildup; clean if accessible.
- Reset control: After cleaning, unplug for 5 minutes, then run a small load to test operation.
- Replace sensor if needed: If E71 continues, replace the pressure sensor. Persistent issues after sensor replacement may indicate a control board problem requiring professional service.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Water Level Pressure Sensor
Check Price on Amazon