E71
GE Profile Water Level Signal Out of Range

Washer shows E71 and may overfill, underfill, or stop with water at an incorrect level.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Pressure hose partially blocked, Sensor calibration drift, Air leak at tub air dome, Control board level calibration fault

How to Fix / Troubleshooting

Safety first: Unplug the washer before inspection.

  • Check for over-sudsing: Excess detergent can create foam that interferes with pressure sensing. Run a rinse & spin with no detergent to clear suds.
  • Inspect pressure hose and air dome: Verify the hose is firmly attached at both ends and not cracked. Inspect the tub air dome (where the hose connects) for buildup; clean if accessible.
  • Reset control: After cleaning, unplug for 5 minutes, then run a small load to test operation.
  • Replace sensor if needed: If E71 continues, replace the pressure sensor. Persistent issues after sensor replacement may indicate a control board problem requiring professional service.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Water Level Pressure Sensor
Check Price on Amazon

We may earn a commission from links on this page.