F51
Miele
Unbalance Detection Fault
Unbalanced load detected, spin aborted, F51 displayed
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Severely unbalanced load, Worn shock absorbers, Faulty unbalance sensor, Loose concrete counterweights
How to Fix / Troubleshooting
Safety first: Unplug before internal checks.
- Redistribute load: Open the door, separate heavy items (e.g., towels, duvets), and run a spin again.
- Check installation: Ensure the washer is level and all four feet are firmly on the floor.
- Inspect suspension: Remove rear or front panel and inspect shock absorbers and springs for oil leakage or breakage.
- If shocks are worn: Replace the Miele shock absorbers in pairs.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Shock Absorbers
Check Price on Amazon