F51
Miele Unbalance Detection Fault

Unbalanced load detected, spin aborted, F51 displayed

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Severely unbalanced load, Worn shock absorbers, Faulty unbalance sensor, Loose concrete counterweights

How to Fix / Troubleshooting

Safety first: Unplug before internal checks.

  • Redistribute load: Open the door, separate heavy items (e.g., towels, duvets), and run a spin again.
  • Check installation: Ensure the washer is level and all four feet are firmly on the floor.
  • Inspect suspension: Remove rear or front panel and inspect shock absorbers and springs for oil leakage or breakage.
  • If shocks are worn: Replace the Miele shock absorbers in pairs.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Shock Absorbers
Check Price on Amazon

We may earn a commission from links on this page.