F55
Miele
Pressure Sensor / Water Level Fault
Water level not detected correctly, F55 displayed
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Blocked pressure chamber, Clogged pressure hose, Faulty electronic pressure sensor, Loose sensor connector
How to Fix / Troubleshooting
Safety first: Unplug the washer.
- Locate pressure system: Remove top or side panel to find the pressure sensor and its thin hose leading to the tub or pressure chamber.
- Check hose: Remove the hose and blow through it gently to clear soap residue. Ensure it is not split or kinked.
- Clean pressure chamber: If accessible, clean out sludge from the chamber on the tub where the hose connects.
- Reconnect and test: Refit hose securely and run a rinse/spin. If F55 persists, the pressure sensor may need replacement.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Electronic Pressure Sensor
Check Price on Amazon
We may earn a commission from links on this page.