F3E3
Roper
Water Inlet Temperature Sensor or Thermistor Range Error
Washer displays F3E3 and may not fill correctly with hot or cold water.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Thermistor reading out of expected range, Incorrect water supply temperature, Thermistor wiring issue, Control misreading sensor
How to Fix / Troubleshooting
Safety First: Unplug the washer and turn off water supply before servicing.
- Step 1 – Check water supply temperature: Run hot and cold water at the nearest faucet. Ensure hot is hot and cold is cold. Correct any plumbing cross-connections.
- Step 2 – Inspect thermistor (if separate from F3E2 sensor): Locate the inlet temperature sensor and check wiring and connector for damage.
- Step 3 – Reset control: After verifying supply temperatures, unplug washer for 5 minutes, then retry a cycle.
If F3E3 persists and the thermistor and wiring check good, the main control may require replacement.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Water Temperature Sensor (Thermistor)
Check Price on Amazon