Possible Causes

Clogged inlet screens at water valves, Household water supply valves partially closed, Kinked inlet hoses, Failed water inlet valve assembly

How to Fix / Troubleshooting

Safety First: Unplug the washer and turn off both hot and cold water supply valves before disconnecting hoses.

  • Step 1 – Verify water supply: Confirm both hot and cold faucets are fully open. Check water pressure at a nearby sink.
  • Step 2 – Inspect inlet hoses: Look for kinks or sharp bends. Straighten or replace hoses as needed.
  • Step 3 – Clean inlet screens: Disconnect hoses at the washer. Use needle-nose pliers to gently remove the small screens in the valve inlets. Rinse debris away and reinstall.
  • Step 4 – Test fill: Reconnect hoses, turn on water, plug in washer, and run a fill test. Listen for valve operation.

If water flow is still poor and household pressure is good, replace the water inlet valve assembly.

Advertisements

Repair Difficulty

Medium 3/5

Required Part

Water Inlet Valve Assembly