F8E1
Roper
Long Fill / Low Water Flow
Washer displays F8E1 or LO FL and fills very slowly or not at all; may time out before wash begins.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Clogged inlet screens at water valves, Household water supply valves partially closed, Kinked inlet hoses, Failed water inlet valve assembly
How to Fix / Troubleshooting
Safety First: Unplug the washer and turn off both hot and cold water supply valves before disconnecting hoses.
- Step 1 – Verify water supply: Confirm both hot and cold faucets are fully open. Check water pressure at a nearby sink.
- Step 2 – Inspect inlet hoses: Look for kinks or sharp bends. Straighten or replace hoses as needed.
- Step 3 – Clean inlet screens: Disconnect hoses at the washer. Use needle-nose pliers to gently remove the small screens in the valve inlets. Rinse debris away and reinstall.
- Step 4 – Test fill: Reconnect hoses, turn on water, plug in washer, and run a fill test. Listen for valve operation.
If water flow is still poor and household pressure is good, replace the water inlet valve assembly.