Rosières
Continuous Fill and Drain (Siphoning or Level Fault)
Washer fills and drains repeatedly without progressing to wash.
Advertisements
Possible Causes
Drain hose inserted too far into standpipe causing siphoning, Drain hose positioned too low, Faulty pressure switch not detecting level, Control fault
How to Fix / Troubleshooting
Safety first: Unplug the washer and turn off water supply.
Step-by-step checks:
- Correct drain hose height: Ensure the drain hose is installed at the height specified in the Rosières manual (usually 60–100 cm above floor) and not sealed airtight into the standpipe.
- Prevent siphoning: Form a high loop in the hose and secure it.
- Check pressure system: Inspect and clean the pressure hose and switch as described in E04/E11.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Pressure Switch
Check Price on Amazon