E Ub
Speed Queen Severe Out-of-Balance Detection (Front-Load)

Front-load washer displays E Ub; severe unbalance during spin, cycle aborts.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Worn shock absorbers, Broken suspension springs, Overloaded drum, Uneven floor or improper leveling

How to Fix / Troubleshooting

Safety: Wait for drum to stop before opening door.

  • 1. Reduce and redistribute load: Remove some items if the drum is overfilled. Spread remaining items evenly.
  • 2. Level the washer: Adjust leveling feet so the washer is stable and does not rock.
  • 3. Inspect shocks: Unplug the washer and remove front or rear panel to access shock absorbers. Replace any that are leaking oil or have weak resistance.
  • 4. Check springs: Inspect suspension springs for stretching or breakage. Replace as needed.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Shock Absorbers
Check Price on Amazon