Possible Causes
Worn shock absorbers, Broken suspension springs, Overloaded drum, Uneven floor or improper leveling
How to Fix / Troubleshooting
Safety: Wait for drum to stop before opening door.
- 1. Reduce and redistribute load: Remove some items if the drum is overfilled. Spread remaining items evenly.
- 2. Level the washer: Adjust leveling feet so the washer is stable and does not rock.
- 3. Inspect shocks: Unplug the washer and remove front or rear panel to access shock absorbers. Replace any that are leaking oil or have weak resistance.
- 4. Check springs: Inspect suspension springs for stretching or breakage. Replace as needed.