LED_2_FLASH
American Water Heaters Pressure Switch or Venting Fault (Power Vent Models with LED Codes)

Gas control status light flashes 2 times repeatedly; burner will not light.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Blocked vent, Failed pressure switch, Disconnected pressure tubing, Faulty blower proving circuit

How to Fix / Troubleshooting

Safety: Turn off power and gas. Do not operate with a suspected vent blockage.

  • 1. Check vent termination: Inspect outside vent for obstructions and clear any debris.
  • 2. Inspect pressure tubing: Ensure tubing between blower and pressure switch is intact and not kinked or filled with water.
  • 3. Test pressure switch: With a multimeter, verify the switch closes when the blower runs. Replace if it fails to close.
  • 4. Verify blower operation: Confirm the blower starts and runs smoothly. Replace blower if it fails to start or is noisy and weak.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Pressure Switch
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements