Ariston
No Power / Supply Failure
Ariston water heater does not power on; no lights or display.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Tripped breaker or blown fuse, Faulty power switch on heater, Loose or disconnected supply wiring, Internal thermal fuse open on control board
How to Fix / Troubleshooting
Safety first: Before opening the unit, turn off the breaker and verify absence of voltage.
- Check breaker and fuses: Reset the breaker and replace any blown fuses with correct ratings. If they trip again, investigate further before resetting.
- Verify supply voltage: Measure voltage at the heater's terminal block. If no voltage, trace back to the distribution panel.
- Inspect internal connections: Ensure the power switch (if present) is ON and that all internal connectors are firmly seated.
- Check thermal fuse (if accessible): Some Ariston models have a non-resettable thermal fuse on the board. If open, the board usually must be replaced.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Power Switch / Electronic Control Board
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements