E07
Ariston
Fan or Air Pressure Switch Fault
Ariston gas water heater displays E07 and will not run; often associated with fan-type models.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Failed combustion fan motor, Blocked fan wheel or air path, Faulty air pressure switch, Disconnected or cracked pressure tubing
How to Fix / Troubleshooting
Safety first: Isolate gas and electrical power. Do not bypass safety devices.
- Access fan assembly: Remove the front cover. Locate the combustion fan and air pressure switch (small round device with tubing).
- Check fan rotation: With power briefly restored, observe if the fan attempts to start (do not leave covers off during extended operation). If it hums but does not spin, the motor may be seized.
- Inspect for obstructions: With power off, spin the fan wheel by hand. Remove any debris and ensure it rotates freely.
- Inspect pressure tubing: Check silicone tubes from the fan housing to the pressure switch for splits, kinks, or disconnections. Refit or replace as needed.
- Test pressure switch: Using a multimeter, verify continuity change on the switch when gently applying suction/pressure to the tube (only if you are trained to do so).
If the fan or pressure switch is defective, replacement is recommended to be carried out by a certified gas technician due to combustion safety implications.
Advertisements
Repair Difficulty
Professional Required
5/5
Required Part
Combustion Fan Assembly
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements