Atlantic Restricted Cold Water Inlet / Safety Group Blockage

Atlantic water heater does not fill with water or fills very slowly.

Advertisements

Possible Causes

Closed or partially closed inlet valve, clogged safety group, debris in inlet filter, collapsed flexible hose

How to Fix / Troubleshooting

Safety: Turn off power. Open a hot water tap to relieve pressure before disconnecting any pipes.

  • Verify that the main cold water shutoff valve and the valve on the Atlantic safety group are fully open.
  • Check the flexible hose to the heater for kinks or collapse; straighten or replace if necessary.
  • Close the inlet valve, remove the safety group or inlet filter (if fitted), and inspect for debris or scale; clean or replace as needed.
  • Reassemble, open the inlet valve, and confirm that water flows freely from an open hot tap until all air is purged.