E12
Atlantic Compressor Overload / Overcurrent Protection

Atlantic heat-pump water heater displays E12; compressor does not start or stops quickly.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Locked compressor, faulty compressor start device, incorrect supply voltage, shorted compressor windings, defective inverter module (on inverter models)

How to Fix / Troubleshooting

Safety: Isolate power. High-voltage and refrigerant components are hazardous; advanced diagnostics should be done by qualified personnel.

  • Verify supply voltage at the heater terminals matches the rating plate (e.g., 230 V single-phase).
  • Inspect the compressor contactor or inverter module for burn marks or loose connections.
  • On non-inverter models, check the compressor start relay and capacitor; replace if visibly damaged or out of specification.
  • Measure compressor winding resistances and insulation resistance to earth with appropriate instruments. If windings are shorted or open, the compressor must be replaced by a refrigeration technician.
  • If the compressor is mechanically locked or the inverter module is faulty, contact an authorized Atlantic service center for compressor or inverter replacement.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Compressor Assembly