E04
Beretta
Flame Detection Fault
E04 displayed; burner lights then goes out
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Dirty ionization electrode, Poor earth, Unstable gas supply, Faulty PCB flame circuit
How to Fix / Troubleshooting
Safety: Turn off gas and power before cleaning electrodes.
- 1. Clean ionization electrode: Remove and gently clean with fine abrasive pad.
- 2. Check earth connection: Ensure the appliance is properly earthed.
- 3. Gas supply check: Have a technician verify gas pressure and stability.
- 4. PCB check: Replace main PCB if flame circuit is defective.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Flame ionization electrode
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements