09
Biasi
Domestic Hot Water (DHW) NTC Sensor Fault
Error 09; appliance locks out and may show abnormal temperature readings.
Advertisements
Possible Causes
Failed DHW temperature sensor, Loose DHW NTC connection, Shorted sensor cable, Scale buildup around sensor pocket
How to Fix / Troubleshooting
Safety: Isolate electrical power and close water valves if removing any wet components.
Steps:
- Locate DHW NTC: Find the sensor on the domestic hot water outlet or on the plate heat exchanger.
- Inspect and clean: Check for corrosion or scale around the sensor. Remove and clean the sensor tip and pocket if accessible.
- Check wiring: Ensure the sensor cable is intact and firmly connected to the control board.
- Test or replace: If you have a multimeter, test resistance versus temperature. If readings are erratic or out of spec, replace the DHW NTC sensor.
Tip: After replacement, verify that the displayed hot water temperature is realistic when running a tap.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
DHW Temperature Sensor (NTC)
Check Price on Amazon
We may earn a commission from links on this page.