09
Biasi Domestic Hot Water (DHW) NTC Sensor Fault

Error 09; appliance locks out and may show abnormal temperature readings.

Advertisements

Possible Causes

Failed DHW temperature sensor, Loose DHW NTC connection, Shorted sensor cable, Scale buildup around sensor pocket

How to Fix / Troubleshooting

Safety: Isolate electrical power and close water valves if removing any wet components.

Steps:

  • Locate DHW NTC: Find the sensor on the domestic hot water outlet or on the plate heat exchanger.
  • Inspect and clean: Check for corrosion or scale around the sensor. Remove and clean the sensor tip and pocket if accessible.
  • Check wiring: Ensure the sensor cable is intact and firmly connected to the control board.
  • Test or replace: If you have a multimeter, test resistance versus temperature. If readings are erratic or out of spec, replace the DHW NTC sensor.

Tip: After replacement, verify that the displayed hot water temperature is realistic when running a tap.

Advertisements

Repair Difficulty

Easy 2/5

Required Part

DHW Temperature Sensor (NTC)
Check Price on Amazon

We may earn a commission from links on this page.