14
Biasi Room Thermostat / External Control Fault

Error 14; unit may not respond to thermostat or control signals.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Open circuit room thermostat, Faulty external control wiring, Incorrect control settings, Faulty PCB input

How to Fix / Troubleshooting

Safety: Isolate power before working on control wiring.

Steps:

  • Check external controls: Ensure the room thermostat or programmer is calling for heat (set temperature higher than room temperature, ensure timers are on).
  • Inspect wiring: At the heater's control terminals, verify that the thermostat wires are secure and not corroded.
  • Bypass test (qualified persons only): Temporarily link the room thermostat terminals at the heater to simulate a call for heat. If the heater starts, the external control or its wiring is faulty.

Warning: Only competent persons should perform bypass tests, and links must be removed after testing. Incorrect wiring can damage the PCB.

Advertisements

Repair Difficulty

Medium 3/5

Required Part

Room Thermostat / Control Wiring
Check Price on Amazon