Biasi
Overheating DHW / Poor Temperature Control
Hot water is scalding hot even at low tap flow, or temperature overshoots setpoint.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Faulty DHW NTC sensor, Sticking gas valve, Incorrect parameter settings, Scale restricting flow
How to Fix / Troubleshooting
Safety: Risk of scalding. Reduce hot water use until the fault is corrected.
Steps:
- Lower DHW set temperature: Use the control panel to reduce the hot water temperature setting.
- Check DHW NTC sensor: Inspect and, if necessary, replace the DHW temperature sensor.
- Descale plate heat exchanger: Restricted flow through a scaled exchanger can cause rapid temperature rise; descale or replace as needed.
Important: If temperature remains unstable after sensor and descaling work, a technician must check gas valve modulation and control parameters.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
DHW Temperature Sensor (NTC) or Plate Heat Exchanger
Check Price on Amazon