Biasi Inadequate DHW Temperature / Temperature Fluctuation

Water heater runs but hot water temperature fluctuates or is not hot enough at taps.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Scaled plate heat exchanger, Faulty DHW NTC sensor, Partially blocked inlet filter, Incorrect flow rate (too high)

How to Fix / Troubleshooting

Safety: Turn off power and close water isolation valves before removing any water-carrying components.

Steps:

  • Check tap flow rate: If water flow is very high, the heater may not be able to raise temperature sufficiently. Partially close the hot tap to reduce flow and see if temperature stabilises.
  • Clean cold inlet filter: Remove and clean the cold water inlet filter to ensure proper flow through the heater.
  • Descale plate heat exchanger (user-level): If accessible and with isolation valves fitted, remove the plate heat exchanger and soak in a manufacturer-approved descaling solution. Rinse thoroughly before refitting.
  • Verify temperature setting: Ensure the DHW temperature setpoint on the control panel is correctly adjusted.

Note: Severe scaling or sensor faults may require professional service and part replacement.

Advertisements

Repair Difficulty

Medium 3/5

Required Part

DHW Plate Heat Exchanger
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements