C6
Bosch Fan Speed Calibration / Combustion Control Error

Bosch tankless water heater shows C6; fan speed or combustion control issue

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Incorrect fan calibration, Fan speed sensor malfunction, Control board firmware issue, Venting outside design parameters

How to Fix / Troubleshooting

Safety first: Turn OFF power and gas. Combustion adjustments affect safety and emissions.

  • Check venting: Confirm that vent length, diameter, and termination meet Bosch specifications. Correct any obvious installation issues.
  • Inspect fan and wiring: Ensure the combustion fan spins freely and that its wiring harness is secure.
  • Reset / recalibrate (if supported): Some models allow a fan calibration or reset procedure via the control panel. Follow the service manual instructions exactly.
  • Professional service: If C6 persists, a technician should verify combustion with a flue gas analyzer and replace the fan or control board if necessary.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Main Control Board (PCB)
Check Price on Amazon

We may earn a commission from links on this page.