Bradford White T&P Relief Valve Discharge

Water leaking from the side of the Bradford White water heater near the T&P (temperature and pressure) relief valve or discharge pipe.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Excessive tank pressure, Overheating water, Failed T&P valve not sealing, Thermal expansion with no expansion tank

How to Fix / Troubleshooting

Safety: The T&P valve is a critical safety device. Do not cap or plug the discharge pipe. Water may be extremely hot.

Steps:

  • Check temperature setting: Ensure the thermostat is not set too high. Reduce to 120°F–130°F.
  • Test T&P valve: Lift the test lever briefly to flush debris, then release. If it continues to drip, the valve may be faulty and should be replaced.
  • Check system pressure: Install a pressure gauge on a nearby faucet. If pressure exceeds 80 psi or rises significantly when heater runs, install or service a thermal expansion tank and pressure-reducing valve.

Always replace a suspect T&P valve with the correct Bradford White-rated part. If you are unsure, hire a licensed plumber.

Advertisements

Repair Difficulty

Medium 3/5

Required Part

Temperature and Pressure Relief Valve
Check Price on Amazon

We may earn a commission from links on this page.