E07
Chaffoteaux Air Pressure Switch / Fan Proving Fault

E07 error, fan may run but ignition does not occur; sometimes accompanied by flue-related warnings.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Blocked flue or condensate trap, Faulty air pressure switch, Split or blocked pressure tubing, Fan not reaching speed

How to Fix / Troubleshooting

Safety: Isolate power and gas. Do not operate with a suspected flue fault.

  • Check condensate trap and drain: On condensing Chaffoteaux models, remove the condensate trap, empty and flush it, and ensure the drain hose is clear and correctly routed.
  • Inspect flue system: Verify that the flue is correctly assembled, not sagging, and free from obstructions at the terminal.
  • Examine pressure switch tubing: Remove the silicone tubes from the air pressure switch and fan connection points. Check for water, cracks, or blockages. Blow through gently to clear any debris and refit securely.
  • Test air pressure switch: With a multimeter, check continuity across the switch terminals while the fan runs (requires live testing by a competent person). If the switch does not change state, replace it.
  • Check fan operation: If the fan is noisy, slow to start, or does not run, it may be failing and should be replaced.