E14
Chaffoteaux Flue Gas NTC Sensor Fault

E14 displayed, often associated with flue gas temperature sensor issues on condensing models.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Defective flue gas NTC, Damaged sensor wiring, Overheated flue due to blockage, Loose sensor in flue hood

How to Fix / Troubleshooting

Safety: Turn off power and gas. Risk of flue gas spillage if flue is blocked.

  • Inspect flue gas sensor: Locate the NTC sensor on the flue hood or outlet. Check that it is firmly fixed and not hanging loose.
  • Check wiring: Follow the cable back to the PCB, looking for heat damage or cuts. Reseat connectors.
  • Measure resistance: Disconnect the sensor and measure resistance at ambient temperature. Compare with manufacturer data. Replace if out of range.
  • Check for flue blockage: If the sensor shows signs of overheating (discoloration), inspect the flue for partial blockage and correct any installation issues.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Flue Gas NTC Sensor
Check Price on Amazon