CTC
Overheating / Thermostat Out of Calibration
Water is too hot; risk of scalding from CTC water heater
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Thermostat set too high, Stuck thermostat contacts, Failed mixing valve, Faulty temperature sensor
How to Fix / Troubleshooting
Safety first: Turn off power and allow water to cool. Open a hot tap to relieve pressure.
Steps to check:
- Lower the set temperature on the CTC control panel to a safe level (around 49°C / 120°F).
- For mechanical thermostats, verify that the dial setting matches actual outlet temperature using a thermometer.
- Inspect and test the thermostatic mixing valve; replace if it does not regulate temperature correctly.
- If temperature continues to overshoot the setpoint, replace the tank thermostat / temperature sensor and, if needed, the main control PCB.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Thermostatic Mixing Valve
Check Price on Amazon
We may earn a commission from links on this page.