Insufficient Outlet Temperature
Water heater runs but hot water temperature is too low at all taps
Advertisements
Possible Causes
DHW setpoint too low on De Dietrich controller, Scaled plate heat exchanger, Faulty DHW NTC sensor, Excessive cold mixing via thermostatic mixing valve
How to Fix / Troubleshooting
Safety first: Beware of scalding when increasing temperature settings.
Step-by-step checks:
- Check set temperature: Use the control panel to verify the DHW setpoint (often adjustable between 40–60°C). Increase slightly if set too low.
- Test at a single tap: Run hot water at one tap only to see if temperature improves. If it does, the system may be undersized for simultaneous use.
- Check mixing valve: If a thermostatic mixing valve is installed near the cylinder, ensure it is not set too low or stuck. Adjust according to manufacturer instructions.
When to call a professional: Persistent low temperature may indicate a scaled heat exchanger or faulty sensor requiring service.