E10
Dimplex Low / No Water Flow Detected

E10 error; unit will not start heating when hot tap is opened

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Blocked inlet filter, Partially closed isolation valve, Limescale in flow path, Faulty flow sensor not registering low flows

How to Fix / Troubleshooting

Safety: Turn off electrical power and close the water supply before disassembly.

  • Check valves: Confirm that the cold water isolation valve to the Dimplex heater is fully open. Check any upstream stopcocks or pressure-reducing valves.
  • Clean inlet filter: Disconnect the cold inlet union and remove the mesh filter. Clean thoroughly under running water and reinstall.
  • Descale flow path: If in a hard water area, consider descaling the inlet and heat exchanger using a pump and approved descaling solution, following Dimplex instructions.
  • Test flow sensor: With power off, remove and inspect the flow sensor. Clean any debris and ensure free movement. Replace if worn or seized.

Test: Restore water and power, then open a hot tap fully. If E10 persists despite good flow, the flow sensor or PCB may need replacement.

Advertisements

Repair Difficulty

Medium 3/5

Required Part

Inlet Filter and Flow Sensor