E16
Dimplex Temperature Sensor Short Circuit

E16 error; unit reports sensor short circuit

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

NTC sensor leads shorted together, Water ingress into sensor connector, Crushed sensor cable, Faulty control PCB input

How to Fix / Troubleshooting

Safety: Isolate power before testing sensors.

  • Inspect sensor wiring: Trace the affected NTC sensor cable (inlet or outlet) and look for crushed or pinched sections where conductors may be shorted.
  • Check connector: Disconnect the sensor from the PCB and inspect for moisture or corrosion. Dry and clean as needed.
  • Measure resistance: With the sensor disconnected, measure resistance across its leads. A reading near 0 ohms indicates a shorted sensor that must be replaced.

Note: If the sensor tests normal but E16 persists, the PCB input circuit may be shorted and require board replacement.