Possible Causes

Flow sensor calibration drift, Partially blocked inlet filter, Incorrectly sized flow restrictor, Low supply pressure

How to Fix / Troubleshooting

Safety: Turn off power and water before removing filters.

  • Clean inlet filter: Remove and clean the cold inlet filter to reduce restriction.
  • Check supply pressure: Measure static and dynamic pressure. Install a booster pump if pressure is below Dimplex minimum.
  • Inspect flow sensor: Replace the flow sensor if it fails to detect low flows.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Flow Sensor / Inlet Filter