Dimplex
Minimum Flow Threshold Too High
Water heater only works when more than one hot tap is open
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Flow sensor calibration drift, Partially blocked inlet filter, Incorrectly sized flow restrictor, Low supply pressure
How to Fix / Troubleshooting
Safety: Turn off power and water before removing filters.
- Clean inlet filter: Remove and clean the cold inlet filter to reduce restriction.
- Check supply pressure: Measure static and dynamic pressure. Install a booster pump if pressure is below Dimplex minimum.
- Inspect flow sensor: Replace the flow sensor if it fails to detect low flows.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Flow Sensor / Inlet Filter
Check Price on Amazon