Possible Causes
Tripped circuit breaker, blown internal fuse, loose mains connection at terminal block, faulty power switch on heater
How to Fix / Troubleshooting
Safety: Only qualified persons should work on electrical circuits. Always verify power is OFF before touching terminals.
Steps:
- Check the household breaker or fuse feeding the heater and reset or replace if tripped/blown. If it trips again immediately, there is a fault that must be diagnosed.
- Remove the terminal cover on the heater and verify that supply voltage is present at the terminal block.
- Inspect and tighten all terminal screws.
- Locate any internal fuses on the control board or near the terminal block; test and replace with identical types if blown.
- Test the heater's main power switch (if present) for continuity; replace if defective.