Drazice No Power / Supply Failure

Drazice water heater does not turn on at all; no indicator lights or display.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Tripped circuit breaker, blown internal fuse, loose mains connection at terminal block, faulty power switch on heater

How to Fix / Troubleshooting

Safety: Only qualified persons should work on electrical circuits. Always verify power is OFF before touching terminals.

Steps:

  • Check the household breaker or fuse feeding the heater and reset or replace if tripped/blown. If it trips again immediately, there is a fault that must be diagnosed.
  • Remove the terminal cover on the heater and verify that supply voltage is present at the terminal block.
  • Inspect and tighten all terminal screws.
  • Locate any internal fuses on the control board or near the terminal block; test and replace with identical types if blown.
  • Test the heater's main power switch (if present) for continuity; replace if defective.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Internal Fuse
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements