F3
Drazice
Coil Circulation Pump Fault
Drazice combined heater shows F3; circulation pump for coil does not run.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Seized circulation pump, air-locked pump, failed pump relay on control board, blocked pump rotor by debris
How to Fix / Troubleshooting
Safety: Turn OFF power and close isolation valves on the heating circuit if present.
Steps:
- Locate the circulation pump connected to the Drazice heater coil.
- Check electrical connections and ensure the pump is receiving power when there is a call for heat (requires careful live testing by a qualified person).
- With power OFF, loosen the pump vent screw (if provided) and use a screwdriver to gently turn the rotor to free it if stuck. Be prepared for a small water leak.
- Bleed air from the pump and heating circuit using bleed valves.
- If the pump does not run even with correct voltage, replace the pump with a compatible circulation pump.
- If no voltage is present at the pump when expected, the control board relay may be faulty and the board may need replacement.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Coil Circulation Pump