F5
Drazice Anti-Legionella Cycle Fault

Drazice digital heater shows F5; anti-legionella function fails or stops mid-cycle.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Insufficient heating capacity due to failed element, incorrect time or temperature settings, sensor misreading, control board error

How to Fix / Troubleshooting

Safety: Turn OFF power before opening covers.

Checks:

  • Verify that the heating element and thermostat are working by checking if the heater can reach the normal set temperature.
  • Enter the settings menu and confirm that the anti-legionella function is enabled and scheduled correctly.
  • Ensure that the maximum temperature limit is set high enough to allow the anti-legionella temperature (typically 60–70°C).
  • Check the main NTC sensor for correct readings; replace if faulty.
  • If the heater cannot reach the required temperature even with a good element and sensor, there may be excessive limescale or a control board issue requiring professional service.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Main NTC Temperature Sensor
Check Price on Amazon