Drazice
Open Heating Element or Tripped Safety Thermostat
Water heater does not heat at all; no hot water from any tap, no error code displayed on mechanical Drazice models.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Burned-out heating element on Drazice flange, tripped manual reset safety thermostat, loose live or neutral connection at terminal block, failed mechanical thermostat
How to Fix / Troubleshooting
Safety: Turn OFF the circuit breaker and verify absence of voltage at the heater terminals before opening the cover.
Steps:
- Remove the access cover to expose the thermostat, safety cut-out, and heating element terminals.
- Press the manual reset button on the safety thermostat until it clicks. If it was tripped, this may restore heating.
- Check that the mechanical thermostat is set to an appropriate temperature (e.g., 55–60°C).
- Inspect and tighten all screw terminals on the terminal block and thermostat.
- With power OFF, disconnect the wires from the heating element and measure resistance across the element. Replace the heating flange assembly if the element is open.
- If the element is good but there is still no heating, replace the mechanical thermostat with a Drazice-compatible unit.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Heating Flange Assembly
Check Price on Amazon
We may earn a commission from links on this page.