E15
EcoSmart Stage Firing / Element Sequencing Fault

Display shows E15; unit may shut down when multiple elements should be active.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed element stage driver on control board, Open heating element in one stage, Incorrect wiring of multi-element modules, Loose stage harness connector

How to Fix / Troubleshooting

Safety: Turn OFF power at the breaker before testing elements or wiring.

  • Check stage wiring: For multi-element EcoSmart models, verify that each element stage harness is connected to the correct terminals on the control board and heating modules.
  • Test each element: Disconnect and measure resistance of each element. An open circuit indicates a failed element that must be replaced.
  • Inspect connectors: Reseat the multi-pin connectors between the control board and element banks.
  • Test operation: After replacing any bad elements and securing connections, restore power and run hot water at high demand to see if E15 recurs.
  • Board replacement: If all elements are good but one stage never energizes and E15 persists, the stage driver on the control board may be defective and require replacement.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Heating Element Bank / Stage Harness
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements