E16
Eemax Low Internal DC Supply / Control Power Fault

Display shows E16; unit may not power up fully or may reset intermittently.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed low-voltage power supply on control board, Loose neutral or line connection, Internal short drawing down supply, Surge damage

How to Fix / Troubleshooting

Safety: Turn OFF power before removing the cover. Internal circuits include both high and low voltage.

Checks:

  • Inspect the line voltage connections at the terminal block for tightness and signs of overheating.
  • Check for any obvious shorts or burned components on the control board.
  • If connections are sound and there is no external cause, the control board's low-voltage power supply is likely defective. Replace the main control board assembly.
  • After replacement, restore power and verify stable operation without resets or E16.

Because this involves internal electronics, board replacement is the standard remedy.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

Main Control Board
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements