E20
Eemax
Calibration / Sensor Range Error
Display shows E20; unit may not heat or may show incorrect temperature.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Thermistors out of calibration, Wrong sensor type installed, Control board calibration data corrupted, Wiring swapped between inlet and outlet sensors
How to Fix / Troubleshooting
Safety: Turn OFF power and close water supply before servicing.
Steps:
- Remove the cover and verify that the inlet and outlet thermistors are connected to the correct terminals on the control board as per the wiring diagram.
- Confirm that replacement sensors (if any) are genuine Eemax parts for your model.
- Measure resistance of both sensors at a known temperature and compare to Eemax charts. Replace any sensor that is out of range.
- If sensors are correct and wired properly, the control board calibration may be corrupted. Replace the main control board.
After repairs, verify displayed temperature against an external thermometer at a faucet.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Outlet Thermistor Sensor
Check Price on Amazon
We may earn a commission from links on this page.