E7
Eemax Control Board Communication / Internal Memory Error

Display shows E7; unit may not respond to temperature adjustments or may shut down.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Corrupted control board firmware, Internal memory fault, Loose display/control panel connection, Electrical surge damage

How to Fix / Troubleshooting

Safety: Turn OFF power at the breaker before accessing internal components.

Reset and inspection:

  • Turn OFF the breaker for at least 5 minutes to allow the control board to fully discharge. Then restore power and check if E7 clears.
  • If the unit has a separate user interface/display board, remove the front cover and inspect the ribbon cable or harness between the display and main control board. Reseat both ends.
  • Check for signs of moisture intrusion or corrosion on the control board. If present, locate and correct the source of moisture (leaks, condensation) and dry the area thoroughly.
  • If E7 persists, the main control board is likely faulty. Replace it with the correct Eemax control board assembly for your model.
  • After replacement, restore power and reprogram any temperature or configuration settings as needed.

Because this error involves internal electronics, board replacement is typically required if a power reset and connector checks do not resolve it.