Eemax Overcurrent / Short Circuit

Unit trips the circuit breaker immediately or shortly after turning on hot water.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Shorted heating element, Shorted wiring to ground, Incorrect breaker size, Internal control board short

How to Fix / Troubleshooting

Critical safety: Do not repeatedly reset a tripping breaker. Turn OFF power and leave it off until the fault is found.

Fault-finding steps:

  • Remove the front cover and visually inspect all wiring and elements for burn marks, melted insulation, or contact with the metal chassis.
  • Disconnect power leads from each heating element and test resistance to ground. Any element showing continuity to ground is shorted and must be replaced.
  • Inspect the control board for obvious shorts or burned components.
  • Verify that the breaker size and wire gauge match the Eemax model's requirements. An undersized breaker may trip under normal load.
  • Replace any shorted heating element or damaged wiring. If no external faults are found, replace the main control board.

If you are not comfortable working with high-current circuits, contact a licensed electrician or technician.

Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Heating Element
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements