E07
Eldom
Earth Leakage / Ground Fault Detected
Eldom heater shows E07; unit may shut down unexpectedly during heating.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Insulation breakdown in heating element, Moisture on wiring or terminals, Faulty earth leakage detection circuit on PCB
How to Fix / Troubleshooting
Critical safety warning: An earth leakage fault can cause electric shock. If you are not experienced with electrical testing, contact a qualified electrician or service technician.
Steps:
- Disconnect power and water: Turn off the breaker and close the water inlet if you will open the tank.
- Check for visible moisture: Remove the lower cover and inspect for water leaks around the element flange and wiring. Dry any moisture and identify the leak source.
- Test element insulation: With wires removed from the element, use a megohmmeter (insulation tester) between each terminal and the metal body. Values below 1 MΩ indicate a failing element; replace it.
- Inspect wiring: Look for damaged insulation where wires may touch the metal casing. Repair or replace damaged wires.
- Control board: If insulation tests are good but E07 persists, the earth leakage detection circuit on the control PCB may be faulty and the board should be replaced.