E08
Eldom Power Supply / Voltage Error

Display shows E08; heater does not heat or only heats intermittently.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Supply voltage out of range, Loose terminal block connections, Internal power supply fault on control PCB

How to Fix / Troubleshooting

Safety: Work only with power off. Mains voltage is lethal.

Steps:

  • Check supply voltage: Have a qualified person measure the voltage at the heater input terminals. Ensure it matches the rating on the Eldom nameplate (e.g., 230 V AC).
  • Inspect terminal block: Remove the cover over the mains connection. Tighten all screws on the terminal block and check for discoloration or melting.
  • Look for burnt components: On the control PCB, inspect the low-voltage power supply section (transformer or SMPS) for burned parts or bulging capacitors.
  • Reset and test: After tightening connections, restore power and see if E08 clears. Persistent E08 with correct voltage usually indicates a defective control PCB.
  • Replace PCB: If internal power supply is faulty, replace the control PCB / power module with an Eldom-approved part.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Eldom Terminal Block / Control PCB
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements